| Output Signals |
Range 0 to 20 mA or 20 to 0 mA
Range 0 to 10 VDC, Typical Adjustments 4-20 mA, 1-5VDC
|
Maximum
input Impedance |
750 ohms
|
| Impedance influence |
<0.05%
|
Dynamic
Output Response |
MSK200-K4 < 100 mSec. (10 to 90%)
MTP200-K4 < 200 mSec. (10 to 90%)
|
| lsolation |
Between input, output and power ports
per EN50 020
|
| Output Filter |
arithmetical Filter1. Order Selectable
between 0 to 99 sec.
|
| Analog Output |
Extracts the root, e.g. for screen
measurements
Output as arithmetic average
Storage of the last output value when disturbed
Max or Min gradient monitoring, rising or falling
characteristic.
time interval 1-999 seconds, adjustable
|
| Options |
Max or Min value storage of the output
signal internet connection
Internet connection for mobile measuring points w.
radio
transmission
|
| Limit Values |
2 relay contact outputs as change-over
contact floating
(option 2 normal open or 2 open).
Two transistor switching outputs for each are available.
The functions Min or Max alarm as well as the operating
modes inoperative or full load current are freely
selectable.
|
| Serial Interface |
RS 232 on the front
socket. Option RS 485 at the connecting
strip with the application of the bus system. |
Maintenance Requirements
Report |
The message are available as a hardware signals relay
R3, quiescent current principle as normally closed
contact
floating and as a software message. For diagnosis
the text
MASK for current errors and a second test
mask for error
memory is shown. Memory information can be selected
easily
to find intermittant errors(e.g.a bad
contact)
|
| Auxiliary Power |
Power supply of the class AC 3 or DC 4 following
IEC654
part 2.
Alternating voltage 24 VAC, -15% / +20%, 50-60 cycles
per
second of DC voltage 24 VDC, -20% / +25%
|
| Temperature Influence |
0.1% within the range
of -20 to %70¡É(-4 to +158 ¢µ) |
| Humidity Influence |
To 95% relative humidity
with no influence |
| EMI Compatibility |
conforms to EN50081-1
and EN50082-2 |
| Connectors |
Shown on data sheets
D97132 for series MTP200 and D97133